Additional Damping Control of DFIG Series Compensated Transmission System Under Sub-Synchronous Resonance

HU Yinghong,DENG Chun,XIE Xiaorong,LI Yu,LIU Hui
DOI: https://doi.org/10.13335/j.1000-3673.pst.2016.04.028
2016-01-01
Abstract:Sub-synchronous resonance may occur in doubly-fed wind turbine series compensated transmission system. In order to better suppress sub-synchronous resonance from DFIG, transfer function of wind power transmission system is derived by modeling wind power series compensation system. Based on transfer function analysis, additional damping control method is proposed. Additional damping control signal tracking synchronous current changes corrects corresponding output voltage. This makes converter present positive resistance in sub-synchronous frequency, effectively inhibiting resonance occurrence. Additional damping control avoids synchronization based on multiple rotating coordinate systems. The strategy does not affect characteristics of original controller. Damping in the method can be adjusted to effectively suppress sub-synchronous resonance. With simulation and experiment, rationality and correctness of additional damping control are validated. The method has advantages of simple calculation and easy realization.
What problem does this paper attempt to address?