Carrier-based modulation algorithm of fault-tolerant three-phase four-switch inverter for better current performance

Chong ZHU,Zhiyong ZENG,Rongxiang ZHAO
DOI: https://doi.org/10.16081/j.issn.1006-6047.2017.05.007
2017-01-01
Abstract:The operational principle of three-phase four-switch inverter is analyzed and a simplified carrierbased modulation algorithm is proposed for it,which only performs simple arithmetic operations on reference voltage to achieve a unified modulation wave expression for four sections,without sector selection and trigonometric operations.It compensates the neutral-point voltage fluctuation of inverter to effectively suppress the distortion of its output current.With the effective ripple current as the assessment criterion,two approaches of zero-vector synthesis are compared,the time-domain analytical expression is deduced and the modulation approach with better output-current performance is determined.The correctness and feasibility of the proposed modulation algorithm are verified by the experimental results.