Experimental Study of Packed-bed Dielectric Barrier Discharge Applied on Ozone Reactor

Jun WEI,Shulou QIAN,Cheng WANG,Weidong XIA
DOI: https://doi.org/10.13336/j.1003-6520.hve.20170731034
2017-01-01
Abstract:In order to improve the concentration and energy efficiency of generated ozone,dielectric particles were packed into space of dielectric barrier discharge (PB-DBD).So we designed a PB-DBD reactor with glass beads and metal powder packed inside the discharge gap,we studied the relationship between the electrical properties of DBD/PB-DBD and ozone concentration,yield,energy efficiency,and power.Moreover,we analyzed the influences of three parameters,such as the cooling water temperature,dielectric loss and energy flux density.The test results show that PB-DBD gets about 40 percent lower ozone generation than DBD when the energy flux density is small,but about 30 percent higher at large energy flux density.Energy efficiency curve rises first and falls later as power increases,and the max ozone concentration is 60 g/m3 when the discharge gap is 2 mm.Low-temperature cooling water is beneficial to ozone generation,such as that PB-DBD reactor using 5 ℃ cooling water gets about 17 percent higher ozone generation than that using 20 ℃ cooling water.Metal powder addition is also important in enhancing discharge and increasing ozone concentration and energy efficiency,which is about 25 percent.
What problem does this paper attempt to address?