A 3D-Graphene Fiber Electrode Embedded with Nitrogen-Rich-carbon-coated ZIF-67 for the Ultrasensitive Detection of Adrenaline

Jinfeng Zeng,Ruoyu Xu,Le Jiao,Yuze Wang,Liwei Chen,Christopher D. Windle,Xiaoteng Ding,Zhipan Zhang,Qing Han,Liangti Qu
DOI: https://doi.org/10.1039/c9tb01223k
IF: 7.571
2019-01-01
Journal of Materials Chemistry B
Abstract:A novel nitrogen-rich-carbon-coated ZIF-67 embedded three-dimensional-graphene (ZIF-67/NC/3DG) fiber was fabricated via a facile one-pot electrodeposition self-assembly method, and used as a prominent electrode for the non-enzymatic detection of adrenaline (Ad). In this design, the prepared ZIF-67 adsorbs Ad through hydrogen bonding and electrostatic interaction, while polypyrrole functions as the precursor of the conductive NC that seamlessly connects ZIF-67 with the 3DG fiber electrode to ameliorate the poor conductivity of the ZIF-67 moiety and thus improve the sensitivity of the ZIF-67/NC/3DG fiber electrode for detecting Ad. The constructed fiber sensor shows a double linear response over the Ad concentration range of 0.06-95 μM with a high sensitivity of 44.6 mA mM-1 cm-2 and 95.0-5900 μM with a good sensitivity of 11.0 mA mM-1 cm-2, giving a low detection limit of 0.02 μM and excellent repeatability. The ZIF-67/NC/3DG fiber electrode was further successfully applied for the determination of Ad in a real sample of human serum, indicating that this fiber electrode is a promising miniaturized sensor for electrochemical analysis.