Highly Responsive and Stable Room Temperature Acetic Acid Gas Sensor Based on Nano-Composite of MXene Ti3C2TX-NiCo2O4-MnO2
Ali Akhtar,Shama Sadaf,Rujun Zhou,Qiang Ling,Si Luo,Mingming Han,Wu Di,Jianqiao Liu,Daru Chen,Xiangfeng Chu
DOI: https://doi.org/10.1016/j.jallcom.2024.177715
IF: 6.2
2024-01-01
Journal of Alloys and Compounds
Abstract:Designing novel acetic acid gas sensors is highly imperative for human health. Two-dimensional (2D) layered MXene Ti3C2Tx is becoming an emerging and promising material in gas sensing. In this manuscript, the hydrothermal method was used to synthesize MXenes Ti3C2Tx/Nb2CTx supported NiCo2O4-MnO2 composites and pure materials. The structure, chemical composition and morphology of the samples were studied by SEM, EDS, TEM, HRTEM, XRD, BET, FTIR, UV-visible, XPS and Raman, justifying the successful synthesis of products. The layered structure of Ti3C2Tx enhanced the BET surface area and provided sufficient sites, which assisted the gas sensing improvement. The gas sensors were fabricated from synthesized products and were tested for different kinds of VOCs deeply. The results exposed that the gas sensor of Ti3C2Tx-NiCo2O4-MnO2 (5% of Ti3C2Tx=NCO-Mn-Ti-5) was highly sensitive to 20 ppm acetic acid and very less responsive to all other VOCs (acetone, TMA, ethanol, methanol, formaldehyde, acetaldehyde, acetylene and xylene) at room temperature. The response (Rg/Ra) to 20 ppm acetic acid was 12.5 and the lowest detection limit was 0.05 ppm. Additionally, the sensor of NCO-Mn-Ti-5 revealed great stability/reproducibility, short response/recovery times and linearity between acetic acid concentration and response. The idea of the novel sensor (NCO-Mn-Ti-5) could be potentially useful in the field of sensors.