Evaluation of a Reverse Transcription-Quantitative Polymerase Chain Reaction (RT-qPCR)-Based Microneutralization Assay for Assessing Clinical Human Cytomegalovirus-Neutralizing Antibody Activity

Jiaao Yu,Maria E. Hasing,Jutta K. Preiksaitis,Xiaoli Pang
DOI: https://doi.org/10.3390/microorganisms12040742
IF: 4.5
2024-04-06
Microorganisms
Abstract:Development of a vaccine for human cytomegalovirus (hCMV) is critical because of the severe consequences of infection in congenitally infected newborns and immunocompromised patients. The assessment of hCMV-neutralizing antibody activity is crucial for vaccine development. This study evaluated a RT-qPCR assay targeting the immediate-early gene transcript of hCMV for determining microneutralizing antibody activity. The assay was evaluated for sensitivity, specificity, and precision using endotheliotropic clinical isolate VR1814 that infects fibroblasts, epithelial, and endothelial cells. The RT-qPCR-based neutralization assay was compared with an immunostaining-based neutralization assay using virions present in hCMV-positive urine, saliva, and breast-milk samples. Our results showed that hCMV replication was detectable at 20 h post-infection with a limit of detection of 1 infectious units (IU)/reaction. The RT-qPCR assay had a dynamic range of 1 to 1.0 × 104 IU/reaction, with coefficients of variation ranging from 0.94% to 15.08%. The RT-qPCR results were in high agreement with the immunostaining assay for hCMV-antibody neutralization assessment. Overall, the RT-qPCR neutralization assay is a reliable, rapid, efficient, and sensitive alternative method for evaluating hCMV-neutralizing activity in vitro.
microbiology
What problem does this paper attempt to address?
The problem this paper attempts to address is the development of a reliable, rapid, and sensitive method to evaluate the activity of human cytomegalovirus (hCMV) neutralizing antibodies. Specifically, the researchers evaluated a micro-neutralization assay based on reverse transcription quantitative polymerase chain reaction (RT-qPCR) for detecting hCMV neutralizing antibody activity in clinical samples. ### Background Human cytomegalovirus (hCMV) infection can lead to severe consequences in newborns and immunocompromised patients, making the development of an effective hCMV vaccine crucial. Evaluating hCMV neutralizing antibody activity is essential for vaccine development. Traditional neutralization assay methods (such as immunostaining) are effective but have drawbacks such as complexity and time consumption. Therefore, the researchers attempted to develop a micro-neutralization assay based on RT-qPCR to improve detection sensitivity and efficiency. ### Objectives 1. **Evaluate the performance of the RT-qPCR micro-neutralization assay**: including sensitivity, specificity, and accuracy. 2. **Compare the performance of the RT-qPCR micro-neutralization assay with traditional immunostaining methods**: to validate the effectiveness and reliability of the new method. 3. **Optimize assay conditions**: to determine the optimal harvest time and detection time points to ensure the accuracy and stability of the assay. ### Methods - **Cells and Virus**: Three cell lines, MRC-5, ARPE-19, and HMEC-1, and the clinical isolate VR1814 were used for the assay. - **RT-qPCR Assay**: Primers targeting hCMV immediate early gene transcripts were designed, and RT-qPCR analysis was performed using the SYBR Green method. - **Immunostaining Method**: As a control method, immunostaining was performed using an anti-CMV IE1 monoclonal antibody. - **Clinical Samples**: Urine, saliva, and breast milk samples were included to evaluate hCMV neutralizing antibody activity from different sources. ### Results - **Sensitivity and Specificity**: The detection limit of the RT-qPCR micro-neutralization assay was 1 infectious unit (IU)/reaction, with a sensitivity of 100%. The detection limit of the immunostaining method was 10 IU/reaction. - **Accuracy**: The coefficient of variation for the RT-qPCR assay ranged from 0.94% to 15.08%, indicating good accuracy. - **Time Point Optimization**: It was determined that samples collected after 20 hours could be accurately detected by RT-qPCR. - **Comparison with Immunostaining Method**: The results of the RT-qPCR assay were highly consistent with the immunostaining method, indicating its reliability in evaluating hCMV neutralizing antibody activity. ### Conclusion The RT-qPCR micro-neutralization assay is a reliable, rapid, efficient, and sensitive method suitable for in vitro evaluation of hCMV neutralizing antibody activity. This method has the potential to become an alternative to traditional immunostaining methods, providing strong support for hCMV vaccine development.