An Experimental Investigation on Transpiration Cooling of a Nose Cone Model with a Gradient Porosity Layout

Nan Wu,Jianhua Wang,Fei He,Guangqi Dong,Longsheng Tang
DOI: https://doi.org/10.1016/j.expthermflusci.2019.05.002
IF: 3.2
2019-01-01
Experimental Thermal and Fluid Science
Abstract:The optimal design of porosity layout within the porous matrix to enhance stagnation-point cooling effect and reduce coolant load is one of the key topics in the research field of transpiration cooling. This paper presents an experimental investigation on the effect of porosity layout and coolant mediums on the transpiration cooling performances. Two nose cone specimens were manufactured and used, one is named as "uniform porosity layout (UPL)", and the other is "gradient porosity layout (GPL)", where the porosity is locally enlarged near the leading edge. In compared with UPL, GPL is better in utilizing coolant, and the required coolant injection pressure is reduced. For GPL, the influence of coolant mediums (i.e. cooling air and liquid water) is further discussed, and two different cooling behaviors are observed. For GPL/liquid water, with the increase of coolant mass flow ratio, there is a transition from gas-like cooling behavior to liquid-like behavior. Besides, a numerical estimation of maximum heat flux on the nose cone and the required coolant mass flow rate is analyzed.