Status of Steady-State Magnetic Diagnostic for ITER and Outlook for Possible Materials of Hall Sensors for DEMO

Ivan Duran,Slavomir Entler,Ondrej Grover,Inessa Bolshakova,Karel Vyborny,Martin Kocan,Tomas Jirman,George Vayakis,Oleksandr Vasyliev,Maksym Radishevskyi,Zhenxing Wang,Daniel Neumaier
DOI: https://doi.org/10.1016/j.fusengdes.2019.03.201
IF: 1.905
2019-01-01
Fusion Engineering and Design
Abstract:The ITER outer vessel steady state (OVSS) magnetic diagnostic employing bismuth Hall sensors is presently being manufactured. New results on understanding and analytical description of a rather complex dependence of bismuth Hall coefficient on magnetic field and temperature are presented. Both, dependence of bismuth Hall coefficient on temperature and magnetic field is captured by a single analytical function while the error of the fit is comparable to the maximum allowed error of the ITER OVSS diagnostic. Results of FISPACT simulation of indium transmutation under ITER OVSS like neutron fluence are presented. Indium is used within OVSS sensors to provide periodic in-situ recalibration of embedded thermocouples. It is demonstrated that additional impurities introduced by indium transmutation does not compromise precision of the ITER OVSS diagnostic. Finally, outlook for Hall sensing materials (InAs, Bi, BiCu, Sb, Au-nanofilms, and graphene) potentially applicable for DEMO steady state sensors is given reviewing their properties in relation to the harsh environmental constraints posed to their implementation on DEMO reactor.
What problem does this paper attempt to address?