Novel infrared differential optical absorption spectroscopy remote sensing system to measure carbon dioxide emission

Ru-Wen Wang,Pin-Hua Xie,Jin Xu,Ang Li
DOI: https://doi.org/10.1088/1674-1056/28/1/013301
2019-01-01
Chinese Physics B
Abstract:A CO2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy (WFM-DOAS) is developed for measuring CO2 emissions from pollution sources. The system is composed of a spectrometer with band from 900 nm to 1700 nm, a telescope with a field of view of 1.12 degrees, a silica optical fiber, an automatic position adjuster, and the data acquisition and processing module. The performance is discussed, including the electronic noise of the charge-coupled device (CCD), the spectral shift, and detection limits. The resolution of the spectrometer is 0.4 nm, the detection limit is 8.5 x 10(20) molecules.cm(-2), and the relative retrieval error is < 1.5%. On May 26, 2018, a field experiment was performed to measure CO2 emissions from the Feng-tai power plant, and a two-dimensional distribution of CO2 from the plume was obtained. The retrieved differential slant column densities (dSCDs) of CO2 are around 2 x 10(21) molecules.cm(-2) in the unpolluted areas, 5.5 x 10(21) molecules.cm(-2) in the plume locations most strongly affected by local CO2 emissions, and the fitting error is less than 2 x 10(20) molecules.cm(-2), which proves that the infrared remote sensing system has the characteristics of fast response and high precision, suitable for measuring CO2 emission from the sources.
What problem does this paper attempt to address?