Experimental and Numerical Investigation of the Interfacial Properties of Non-Steam-cured UHPC-steel Composite Beams

Zhe Wang,Xin Nie,Jian-Sheng Fan,Xin-Ying Lu,Ran Ding
DOI: https://doi.org/10.1016/j.conbuildmat.2018.11.057
IF: 7.4
2019-01-01
Construction and Building Materials
Abstract:The performance of ultra-high performance concrete (UHPC)-steel composite beams is dependent on the connection between the UHPC and steel. In this study, bending tests were conducted on UHPC-steel composite beams with different interfaces: UHPC directly cast on different plate textures, bonding using an epoxy-based adhesive, and traditional headed studs. The connection between the UHPC and the plates was extremely weak, but the adhesive performed well, failing after the steel beam yielded. Three-dimensional finite element models of the adhesively bonded beams were then established using ABAQUS and agreed well with the test results, successfully predicting the failure of the adhesive bonds.
What problem does this paper attempt to address?