Influence of Axial Self-magnetic Field Component on Vacuum Arc Transition to Diffuse Mode of Transverse Magnetic Field (TMF) Contacts

Zixi Liu,Shixin Xiu,Xiao Wang,Bo Yuan,Rui Li
DOI: https://doi.org/10.1109/deiv.2018.8537178
2018-01-01
Abstract:The motion of arc between TMF contacts gradually slows down and transits to diffusion mode before the current zero crossing. The process of arc transition to diffusion state seriously affects the contact surface ablation. However, the influence of axial self-magnetic field component on vacuum arc transition to diffuse mode has not been deeply studied to date. In this paper, TMF contacts with different structures were investigated in a demountable vacuum chamber that contained a highspeed charge coupled device video camera. The magnetic field characteristics of different TMF contact structures were studied. It was found that the axial self-magnetic field component had significant effects on the arc appearance, the arc column diameter, the moment and the instantaneous current during the transition process to the diffuse mode when the current exceeded 16 kA. The arc column with larger axial self-magnetic field had larger diameter while transiting to diffuse mode. The arc column with larger axial magnetic field also transited to the diffusion arc earlier and accumulated less energy during the transition.
What problem does this paper attempt to address?