High-precision Photogrammetric Surface Figure Measurements under Cryogenic Environment

Lou Zheng,Qian Yuan,Fan Sheng-hong,Liu Chang-ru,Wang Hai-ren,Zuo Ying-xi,Cheng Jin-quan,Yang Ji
DOI: https://doi.org/10.1016/j.chinastron.2017.01.006
2016-01-01
Abstract:Limited by the working temperature of the test equipment, most of high-precision surface figure measurement techniques cannot be put into application under a cryogenic environment. This paper reports the first attempt to measure the surface figure of a high-precision terahertz reflector panel under low temperatures based on photogrammetry. The measurement employs a high-resolution industrial camera sitting on the automatic testing platform which enables photos been taken in an automatic fashion inside a climate chamber. A repeatable accuracy of 2.1 μm (rms) is achieved under the cryogenic environment. Furthermore, the surface figure measured by a three-coordinate measuring machine under the room temperature is used to calibrate the thickness differences of the targets. By this technique, the surface figure of an aluminum prototype panel of the 5 meter Dome A Terahertz Telescope (DATE5) is measured from room temperature down to −55°C to obtain the rule of variation of surface deformation of the panel under low temperatures.
What problem does this paper attempt to address?