Myocardial Protection Effect of Warm Blood Cardioplegia Reperfusion on Warm Ischemic Rat Heart Grafts
刘欢,郑佳予,宋凯,洪涛
DOI: https://doi.org/10.3969/j.issn.1672-8467.2009.02.008
2009-01-01
Abstract:Objective To investigate the myocardial protection effect of warm blood cardioplegia reperfusion on warm ischemic rat heart grafts. Methods Twenty-four SD rats were divided into 3 groups randomly:The control group (A,n=8,WI[Warm Ischemia]=0,CI[Cold Ischemia]=4 h,routine protect procedure); The warm ischemia group (B,n=8,WI=10 min,CI=4 h,routine protect procedure); The warm blood cardioplegia reperfusion group (C,n=8,WI=10 min,CI=4 h,routine protect procedure followed by continuous warm blood cardioplegia reperfusion).After the preservation,Langendorff model was settled,resuscitation of the hearts were observed,the coronary extravasations (blood flow from the coronary sinus in C group) were collected to detect cardiac enzymes.The coronary flow was measured.The intra-left ventricular pressure curve was record and hemodynamic values were calculated.The hearts were harvested for histopathologic study and to determine the percentage of water content. Results The resuscitation was better in group A and C than in group B.The hearts in group A and C got sinus rhythms as soon as reperfusion initiated while all hearts in group B ventricular fibrillated (VF).Seven out of eight hearts in group B could have a sinus rhythm 15 to 20 min after reperfusion started while a heart in this group kept a VF rhythm in one hour of reperfusion with continuous compression.Cardiac enzymes were significantly higher in group B and C [CK:(2 191.25±1 408.08)U/L,(2 918.63±1 194.55)U/L,CK-MB:(82.13±37.08)U/L,(472.25±133.74)U/L,AST:(71.25±27.91)U/L,(323.38±102.98)U/L,LDH:(189.50±71.34)U/L,(1 548.38±943.62)U/L] than in group A [CK:(94.00±99.42)U/L,CK-MB:(14.75±9.33)U/L,AST:(12.13±8.59)U/L,LDH:(35.75±28.95)U/L] (P0.01).Coronary flow in group A was (8.71±1.42)mL/min,which was significantly higher than that in group B [(6.56±1.54)mL/min](P0.05).The coronary flow in group C was (7.96±1.17)mL/min without significant difference from group A (P0.05).The hemodynamic values of heart rate (HR),the biggest positive and negative slope of intra-left ventricle pressure curve (+dp/dt max and-dp/dt max) in group A and C were HR:(248.22±36.56)bpm and (266.07±27.75)bpm,+dp/dt max:(144.32±32.89)kPa/s and (147.04±27.04)kPa/s,-dp/dt max:(126.81±35.07)kPa/s and (141.96±31.83)kPa/s respectively without significant difference between these two groups(P0.05).The HR,+dp/dt max,-dp/dt max in group B were (177.88±83.96)bpm,(41.33±42.13)kPa/s,(31.77±31.14)kPa/s which were significant lower than group A(P0.05).The water content in group B and C were (81.10±1.24)% and (80.52±0.90)% which were significantly higher than group A(78.90±1.33)% (P0.05).Histopathologic damage was more severe in group B than in group A and C. Conclusions Warm blood cardioplegia reperfusion can reduce the ischemia-reperfusion damage in rat heart grafts from NHBDs and improve the resuscitation and hemodynamic performance after reperfusion.