Information Fusion Fault Diagnosis System Based on Fuzzy Neural Network

苏羽,赵海,苏威积,王刚
DOI: https://doi.org/10.3969/j.issn.1000-3428.2004.17.003
2004-01-01
Abstract:Data fusing method is introduced in this paper via constructing blur neural network model. In order to measure stimulant data difference in input temperature of refrigerant, stator temperature and output temperature of refrigerant multi-sensors are set in the hydro-generator group and membership of every sensor about fault is computed and the cause of fault is determined via data fusing method .At last via contrasting fusing result of single sensor and fusing result of multi-sensor it is indicated that fault diagnosis of multi-sensor data fusing is more exact than those of single sensor.
What problem does this paper attempt to address?