Facile Electrochemical Microbiosensor Based on In Situ Self-Assembly of Ag Nanoparticles Coated on Ti 3 C 2 T x for In Vivo Measurements of Chloride Ions in the PD Mouse Brain
Chenchen Li,Yi Zhuo,Xia Xiao,Shuangfu Li,Kai Han,Ming Lu,Jiaxin Zhang,Shu Chen,Hui Gu
DOI: https://doi.org/10.1021/acs.analchem.1c00342
IF: 7.4
2021-05-20
Analytical Chemistry
Abstract:Chloride ion (Cl<sup>–</sup>), one of the most important anions in the brain, has been confirmed to participate in the pathological process of Parkinson's disease (PD). As such, the development of a reliable method for <i>in vivo</i> measurements of Cl<sup>–</sup> is extremely appealing, especially for understanding the pathogenesis of PD. We herein designed a facile electrochemical microbiosensor (ECMB), based on <i>in situ</i> self-assembly of Ag nanoparticles (Ag NPs) coated on Ti<sub>3</sub>C<sub>2</sub>T<i><sub>x</sub></i>. The uniform nanosized Ag NPs were reduced by Ti<sub>3</sub>C<sub>2</sub>T<i><sub>x</sub></i> by a simple dipping process, endowing the ECMB with excellent specificity toward Cl<sup>–</sup> detection and remarkably reproducible preparation process. Meanwhile, electro-oxidized graphene oxide was introduced as an inner reference, thus avoiding the environmental interference of the complicated brain systems to increase the determination accuracy. An extensive <i>in vitro</i> study revealed that the proposed ECMB would be a robust candidate for real-time monitoring of Cl<sup>–</sup> in the PD mouse brain with high selectivity, accuracy, and reproducibility. Moreover, the availability and reliability toward <i>in vivo</i> Cl<sup>–</sup> monitoring of the designed ECMB were well confirmed by comparing with the standard Volhard's method. Finally, by virtue of the successful employment of the developed detecting platform in the <i>in vivo</i> measurement of Cl<sup>–</sup> in the PD mouse brain, systematic analysis and comparison of the average levels of Cl<sup>–</sup> in the three regions including cortex, striatum, and hippocampus of brains from normal and PD model mice have been achieved.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.1c00342?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.1c00342</a>.Experimental details, materials and reagents, apparatus and measurements, fabrication of EMFE, PD model evaluation; AFM image of Ti<sub>3</sub>C<sub>2</sub>T<i><sub>x</sub></i> flakes; SEM images of the specific Ag NPs with different self-assembly times; DPV behaviors of the CFME/OxGO/Ti<sub>3</sub>C<sub>2</sub>T<i><sub>x</sub></i>/Ag electrode with different self-assembly times; EDS mapping image and EDX analysis of the ECMB; comparison on the abilities of different modified electrodes for Ag self-assembly; comparison of the levels of chemical bond components in GO, OxGO, and OxGO/Ti<sub>3</sub>C<sub>2</sub>T<i><sub>x</sub></i>; selection of the reference electrode; selectivity of the ECMB for Cl<sup>–</sup>, Br<sup>–</sup>, and I<sup>–</sup>; reproducibility, stability, and anti-biofouling ability of the proposed ECMB; <i>in vivo</i> DPVs for Cl<sup>–</sup> detection in the hippocampus of the rat brain before and after microinjection of aCSF; comparison of the present ECMB with Volhard's method; evaluation of the PD model; and summary of the <i>in vivo</i> measurements of Cl<sup>–</sup> in the PD mice brain (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.1c00342/suppl_file/ac1c00342_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical