Abstract:This paper explores the issue of the neutral-point oscillation in the four-leg neutral-point clamped inverter. Such an issue is closely associated with the neutral-point current, so this study models the inverter on the dc side to clarify its relationship and presents a three-dimension pulsewidth modulation to eliminate the neutral-point oscillation. In addition, an offset-injection approach to reducing the neutral-point oscillation is also investigated and discussed. The laboratory test results will validate the analysis of the proposed approach, and a discussion will be presented to evaluate the effectiveness of eliminating the neutral-point oscillation.
What problem does this paper attempt to address?