Oscillating diffusion‐encoding with a high gradient‐amplitude and high slew‐rate head‐only gradient for human brain imaging
Ek T. Tan,Robert Y. Shih,Jhimli Mitra,Tim Sprenger,Yihe Hua,Chitresh Bhushan,Matt A. Bernstein,Jennifer A. McNab,J. Kevin DeMarco,Vincent B. Ho,Thomas K. F. Foo
DOI: https://doi.org/10.1002/mrm.28180
2020-02-03
Magnetic Resonance in Medicine
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>We investigate the importance of high gradient‐amplitude and high slew‐rate on oscillating gradient spin echo (OGSE) diffusion imaging for human brain imaging and evaluate human brain imaging with OGSE on the MAGNUS head‐gradient insert (200 mT/m amplitude and 500 T/m/s slew rate).</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Methods</h3><p>Simulations with cosine‐modulated and trapezoidal‐cosine OGSE at various gradient amplitudes and slew rates were performed. Six healthy subjects were imaged with the MAGNUS gradient at 3T with OGSE at frequencies up to 100 Hz and <i>b</i> = 450 s/mm<sup>2</sup>. Comparisons were made against standard pulsed gradient spin echo (PGSE) diffusion in vivo and in an isotropic diffusion phantom. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>Simulations show that to achieve high frequency and b‐value simultaneously for OGSE, high gradient amplitude, high slew rates, and high peripheral nerve stimulation limits are required. A strong linear trend for increased diffusivity (mean: 8–19%, radial: 9–27%, parallel: 8–15%) was observed in normal white matter with OGSE (20 Hz to 100 Hz) as compared to PGSE. Linear fitting to frequency provided excellent correlation, and using a short‐range disorder model provided radial long‐term diffusivities of D<sub>∞,MD</sub> = 911 ± 72 µm<sup>2</sup>/s, D<sub>∞,PD</sub> = 1519 ± 164 µm<sup>2</sup>/s, and D<sub>∞,RD</sub> = 640 ± 111 µm<sup>2</sup>/s and correlation lengths of <i>l<sub>c</sub></i><sub>,MD</sub> = 0.802 ± 0.156 µm, <i>l<sub>c</sub></i><sub>,PD</sub> = 0.837 ± 0.172 µm, and <i>l<sub>c</sub></i><sub>,RD</sub> = 0.780 ± 0.174 µm. Diffusivity changes with OGSE frequency were negligible in the phantom, as expected. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Conclusion</h3><p>The high gradient amplitude, high slew rate, and high peripheral nerve stimulation thresholds of the MAGNUS head‐gradient enables OGSE acquisition for in vivo human brain imaging.</p></section>
radiology, nuclear medicine & medical imaging