From the grating scale monitor to the generalized seeing monitor

A Ziad,R Conan,A Tokovinin,F Martin,J Borgnino,Aziz Ziad,Rodolphe Conan,Andrei Tokovinin,François Martin,Julien Borgnino
DOI: https://doi.org/10.1364/ao.39.005415
IF: 1.9
2000-10-20
Applied Optics
Abstract:An instrument named the grating scale monitor for measuring the outer scale L0 from the angle-of-arrival (AA) fluctuations of a perturbed wave front was developed a few years ago at Nice University. The AA is detected with a 5-ms time resolution by modulation of the stellar image in a small telescope with a grating. One uses the normalized covariance of AA fluctuations to estimate L0. A new version of this instrument, the generalized seeing monitor (GSM) is described. It consists of four identical modules for measuring the AA at four locations on the wave front. A spatiotemporal analysis of these data leads to the determination of seeing epsilon0, outer scale L0, and the wave-front speed. In addition, isoplanatic angle theta0 is determined from scintillation, making the characterization of turbulence with the GSM almost complete. We describe the instrument and make a detailed analysis of its performance and accuracy. Several site-testing campaigns have been conducted with the GSM: at La Silla (Chile), Oukaïmeden (Morocco), Maidanak (Uzbekistan), and Cerro Pachon and Cerro Paranal (Chile). The main results of these campaigns are presented and discussed.
optics
What problem does this paper attempt to address?