A Loop‐mediated Isothermal Amplification‐based Method for Detecting Bursaphelenchus Xylophilus from Monochamus Alternatus

F. Meng,X. Wang,L. Wang,D. Gou,H. Liu,Y. Wang,C. Piao
DOI: https://doi.org/10.1111/efp.12404
2018-01-01
Forest Pathology
Abstract:SummaryThe introduction of the pine wood nematode (PWN), Bursaphelenchus xylophilus, to new areas has impacted on the international economy. Therefore, accurate and reliable detection methods for PWN are essential for the control and management of this pest. A rapid and economic method for detecting PWN may be developed focusing on the PWN vector (Monochamus alternatus). This work standardized a loop‐mediated isothermal amplification (LAMP) method using newly designed primer sequences based on the syg‐2 gene, which encodes the synaptogenesis protein syg‐2. Loop‐mediated isothermal amplification was conducted at 63°C for 60 min using six sets of primers. The result was confirmed by visual observation. A positive reaction was confirmed by SYBR Green I fluorescence dye under light thermal cycling. The lower limit of DNA detection was 51.4 pg/μl in both LAMP and 51.4 ng/μl in PCR. Therefore, the LAMP was 1,000 times more sensitive in DNA detection than PCR. The LAMP is a relatively new, highly accurate and rapid molecular technique that can rapidly detect infectious agents in the field without requiring sophisticated instruments, giving a visually readable result. The method greatly improves detection, without requiring professional knowledge and expensive, sophisticated equipment. Therefore, this system is suitable for quarantine and field detection.