DWI observation on acute ischemic rhabdomyolysis of rabbit models using different b values

Hong ZHANG,Chang-zheng SHI,Xiao-bai WANG,Min GUAN,Fei XIONG,Liang-ping LUO
DOI: https://doi.org/10.13929/j.1003-3289.2012.11.034
2012-01-01
Abstract:Objective: To explore the changes of ADC value in DWI with different b values of acute ischemic rhabdomyolysis (RM) rabbit models. Methods: Hindlimb RM models were established in 23 New Zealand white rabbits by using ligation. The ligated hindlimbs were defined as model group, and the unligated hindlimbs were defined as control group. DWI with b=0 was performed, and then b value was taken as 100-800 and 1000 s/mm2, and the scanning was performed with GE Signa HD 1.5T System. ADC values of vastus lateralis in model group and control group were measured and statistically analyzed. Results: There was no statistical difference between model group and control group in ADC values when b < 300 s/mm2 or >800 s/mm2 (all P>0.05), while there was statistical difference between model group and control group when 300 s/mm2 ≤ b ≤ 800 s/mm2 (all P<0.05). The signal intensity of DWI gradually decreased, ADC value gradually decreased and CNR decreased when b value increased. The quality of image was good (CNR>5) when b ≤600 s/mm2. Conclusion: DWI can be used in early diagnosis on acute ischemic RM. For acute ischemic RM rabbit models, when b = 400 or 500 s/mm2, the quality of image is good and ADC value is accurate, while the diffuse capacity of the diseased muscle can be reflected clearly.
What problem does this paper attempt to address?