Optimization of electro-Fenton in the advanced treatment of coal chemical industry wastewater by response surface methodology

Hongjun HAN,Baolin HOU,Shengyong JIA,Dexin WANG
DOI: https://doi.org/10.11918/j.issn.0367-6234.2015.06.008
2015-01-01
Abstract:To obtain the optimal process parameters, the orthogonal test and response surface methodology coupled with central composite design were applied in the optimization of electro-Fenton process as advanced treatment of coal chemical industry wastewater, and a quadratic model was developed to predict the treatment performance. The results showed that the factors affecting TOC removal in descending order was pH, current density and Fe2+ concentration according to the orthogonal test. The developed quadratic model could predict the response accurately, and the optimal parameters were determined as pH 413, 156 mmol/L of Fe2+ and 1474 mA/cm2 of current density, with the predicted optimal TOC removal efficiency of 6158%. The electro-Fenton could serve as a effective technology for the advanced treatment of coal chemical industry wastewater.
What problem does this paper attempt to address?