Morphological Analysis on Trabeculectomy Blebs with Slit Lamp Adapted Optical Coherence Tomography

ZHANG Yi,WU Qiang,SONG Bei-wen,HU Ping,LU Bing
DOI: https://doi.org/10.3969/j.issn.1674-8115.2007.12.021
2007-01-01
Abstract:Objective To make morphological analysis on the trabeculectomy blebs with slit lamp adapted optical coherence tomography(SL-OCT). Methods Seventy-eight eyes of 62 patients,underwent glaucoma filtering surgery,had the blebs be examined by Heidelberg SL-OCT.The images were recorded automatically and analyzed by the accessorial software. Results In 35 of 45(77.8%) successful blebs,bleb wall thickening was found.In contrast,bleb wall thickening was found in only 4 of 24(16.7%) failed blebs(P0.005).Hyporeflective area around scleral flap was found in 26 of 45(57.8%) successful blebs,in contrast,it was found in only 5 of 24(20.8%) failed blebs(P0.005).High signal reflectivity area supra scleral flap was found in 12 of 45(26.7%) successful blebs,in contrast,it was found in 14 of 24(58.3%) failed blebs(P0.01).The route under scleral flap was not found in 20 of 45(44.4%) successful blebs,in contrast,it was not found in 19 of 24(79.2%) failed blebs(P0.01).In addition,we found internal ostium occlusion in 5 eyes,all of them were filed blebs(P0.005). Conclusion SL-OCT was able to demonstrate features of bleb morphology not visible with the slit lamp in trabeculectomised eyes in each stage after the surgery with non-contact examination.This information may be useful to study the different surgical outcomes and typing the blebs.SL-OCT is a worthy tool to image trabeculectomy blebs.
What problem does this paper attempt to address?