Bate titanium alloys for orthopedic implants: fabrication, X-ray diffraction analysis, and biomechanics

贾庆卫,宁聪琴,丁冬雁,汤亭亭,严孟宁,周新社,戴尅戎
2008-01-01
Abstract:[Objective] To develop new bate titanium alloys made of titanium,niobium and zirconium(Ti-Nb-Zr)which have higher strength,lower moduli of elasticity and better biocompatibility for orthopedic implants.[Methods]Alloy elements including titanium,niobium and zirconium were melted together and forged into forging Ti-Nb-Zr.Four kinds of alloys were developed because of the different proportion of alloy elements.All alloys were studied using X-ray diffraction analysis,biomechanical measurements,and scanning and transmission electron microscopy.[Results]X-ray diffraction analyses showed that all the candidates were beta alloys.The as-cast alloys had the strength values in 584~718 Mpa,elastic modulus values in 59~68 Gpa.The peak-aged alloys had the strength values in 706~874 Mpa,elastic modulus values in 59~66 Gpa,elongation rates in 5.4%~20%.The forging procedure could increase the strength significantly but almost have no influence in elastic modulus of Ti-Nb-Zr.[Conclusion]The Ti-Nb-Zr beta titanium alloys developed in our lab have lower modulus and high strength both.It is a promising material for orthopedic implants.
What problem does this paper attempt to address?