Determination of Methylmercury in Drinking Water by Gas Chromatography with Solid Phase Extraction

Bao-xian LIU,Xin-zhong LI,Miao CHANG,Ben-dong ZOU,Lei HUA
DOI: https://doi.org/10.3969/j.issn.1006-2009.2011.01.013
2011-01-01
Abstract:Adsorbed by sulfhydryl cotton in acidic solution,methylmercury in drinking water was determined by gas chromatograph with ECD.The solid phase extraction was performed by using a multi-channel paralleling device and influence of pH value in water samples on recovery was observed.It was found that good linearity of method obtained in range from 0.050 mg/L to 1.00 mg/L,detection limits 0.03 ng/L at sample volume 1.0 L,RSD of standard and parallel samples <5.0%,spiked recoveries >80%.Some suggestions were made for accurate data by using QA/QC of laboratory including blank through entire procedure along with samples,solution blank,parallel samples,and spiked recoveries.