Parameter Optimization of Tunnel Entrance Buffer Structure Based on Orthogonal Test

LIU Shan-hua,JIANG Qing,WANG Ying-xue
DOI: https://doi.org/10.3969/j.issn.1001-7445.2013.01.014
2013-01-01
Abstract:In order to optimize the parameters of buffer structure of high-speed railway tunnel entrance,the three-dimensional,compressible,viscous,turbulence model of FLUENT was used to carry out numerical simulation of 16 kinds of working mode combination that include four factors and four levels.The test focuses on the influence of the combination of various factors and levels on the decrease rate of the pressure gradient.The studies show that the orthogonal test can effectively reduce the number of tests without reducing the test accuracy;the sequence of influence of the factors on the buffering of the combined buffer structure is the distance between the opening end and the tunnel entrancethe opening ratiothe distance between opening and hood entrance the ratio of the expanded section area to the tunnel section area.The optimal combination of the influencing factors is given in the experimental range.
What problem does this paper attempt to address?