Factors Influencing Data Transfer Rate of Optical RAID

XU Min,XU Xuelei,ZHAO Hongzhi,XU Duanyi
DOI: https://doi.org/10.3321/j.issn:1000-0054.1999.10.033
1999-01-01
Abstract:Theoretical data transfer model of optical RAID is developed on the base of analysis of single optical drive. The length of transferred data, rate ratio of SCSI bus to rate of optical drive and striped block size are analyzed to be factors of influencing data transfer rate of optical RAID. Their influence on data transfer rate of optical RAID is analyzed and verified by experiments. According to theoretical analysis, an optimization method is presented. Experiments indicate that the SCSI bus conflict can be reduced effectively, and data transfer rate can be increased by about 2.5 times by optimization.
What problem does this paper attempt to address?