Research of Determination of Salvianoic Acid A in Salvianoic Acid A for Injection

王磊,于翠翠,刘军锋,刘珂,丁黎
DOI: https://doi.org/10.3969/j.issn.1672-7738.2009.12.010
2009-01-01
Abstract:OBJECTIVE To establish a method for the determination of the content of salvianoic acid A in salvianoic acid A for Injection by RP-HPLC. METHODS Used C18 chromatographic column(250mm×4.6mm;5μm),acetonitrile-0.2% phosphoric acid solution (30:70)(v/v)as mobile phase,and the detector wavelength was 285nm. The salvianoic acid A content was determined with peak area by external reference method. RESULTS The line arrange was from 0. 111 to 2. 664μg (r= 0. 9999). The average recovery was 98. 19% ,the RSD was 1.5%. CONCLUSION The method was simple,sensitive,and feasible for the determination of salvianoic acid A content and quality control of salvianoic acid A for injection.