Wind Load on Integral-Lift Scaffolds for Tall Building Construction
F Yue,Y Yuan,GQ Li,KM Ye,ZM Chen,ZP Wang
DOI: https://doi.org/10.1061/(asce)0733-9445(2005)131:5(816)
2005-01-01
Journal of Structural Engineering
Abstract:The integral-lift scaffolds are widely used in construction of tall buildings in Asia. However, the wind load on scaffolds may be much greater than dead load and be the dominant effect as the scaffolds climb over 150 m in height. The shape coefficient and vibration coefficient are important factors in calculation of wind load. However, there is no available approach at present for determining the two coefficients for calculating the wind load on this temporary structure. In order to determine the shape coefficient of wind pressure on the typical scaffolds, wind tunnel tests have been conducted. The drag coefficients have been measured, which are proved to be identical to the wind shape coefficients. By using random vibration theory, formulae are obtained for predicting the wind vibration coefficients of the scaffolds at the two stages of climbing up and down. The useful guidelines for the safe design of integral-lift scaffolds against winds are proposed in this paper.