Calibration and Observation by Using a Water Level, Current Speed, and Turbidity Monitoring System in Coastal Areas

王爱军,汪亚平,柯贤坤,李占海
DOI: https://doi.org/10.3969/j.issn.1001-6392.2003.03.009
2003-01-01
Abstract::Based upon the principle of water pressure and the light-electric effect, an integrated system of water-level, current-speed and turbidity (WCT) meters has been developed. The sensors of water level and current meter have been calibrated in the standard flume in laboratory. The turbidity meter has been calibrated in the laboratory. And then, a field observation is carried out on the intertidal flat, in order to measure the water level, and five layers of current speed and turbidity synchronously within the water column. The results show that the average of relative error for the current speed is 14.52 % in comparison with that of direct-reading current meter deployed in the same layer. By in situ calibration using water sample filtration, the absolute suspended sediment concentrations are then obtained with a relative error of 21.96 %, which improve the accuracy greatly compared to that of laboratory calibration. Hence, the WCT System can be used for observation of water level, velocity of flow and suspended sediment concentration in the boundary layer study on intertidal flats. During the calibration, the effect of grain size was excluded. Moreover, the accuracy of WCT system is also found to be depended on natural environment (e.g. the seawater temperature and salinity) and characteristics of the instruments.
What problem does this paper attempt to address?