Study on Sub-synchronous Oscillation of Ship Harmonics

ZHANG Kun,XIONG Yi,LIU Zhen,KAN Xin-sheng,ZHA Xiao-ming
DOI: https://doi.org/10.13234/j.issn.2095-2805.2011.5.60
2011-01-01
Abstract:Modern ships have been widely equipped with electric propulsion system.With the ships becoming larger,there are more loads and modern equipments,thus the micro-grid system is also more and more complex.Therefore,the stability of the micro-grid requirements is increasing.The structure of marine power system is firstly described,which is a multi-motor structure and the hybrid system of the AC and DC load.The ship micro-grid harmonic problem is serious.The harmonics and other instability factors could cause sub-synchronous oscillation in the micro-grid system.Then the mechanism of sub-synchronous oscillations is described,based on which a gas turbine five-axis model is innovatively established.The model is simulated using the PSCAD.It can be found that generators are prone to torsion vibration.To avoid the situation,the advantages and disadvantages of the common methods are analyzed one by one.Serial capacitors are used to eliminate some harmonics and to compensate the line.The objective to eliminate and reduce sub-synchronous oscillation is realized.Finally,the method is verified through simulation.
What problem does this paper attempt to address?