Experimental Study on the Single-Layer Plane Cable Net with the Influence of Damages

施刚,左勇志,郑敬杰,霍达
DOI: https://doi.org/10.14006/j.jzjgxb.2010.03.002
2010-01-01
Abstract:During the service of single-layer plane cable net supported glass buildings,as the supporting structure the single-layer plane cable net will inevitably be subjected to different types of damages.In order to study the influence of such damages on the static behavior of the single-layer plane cable net,a full-scale model with the dimension of 4.85m×4.85m and 4×4 grids was designed and constructed.Static tests were conducted after introducing three types of damages including failure of connectors between horizontal and vertical cables,cable prestress loss and cable anchorage failure.The results indicate that,failure of connectors between horizontal and vertical cables almost has no influence on the static behavior of the single-layer plane cable net;the change of nodal displacements induced by the cable prestress loss does not exceed 15%;the cable anchorage failure affects the local part of the single-layer plane cable net significantly,and the induced change of nodal displacements is between 18% and 36%;damages have stronger effect on nodal displacements than cable tension forces.The intensity of the influence of damages depends on the damage degree and location,and decreases with the increase of load.The research results provide a sound foundation for establishing the safety evaluating method of in-service single-layer plane cable net structures.
What problem does this paper attempt to address?