Clinical evaluation of visual quality after CACHET phakic intraocular lens implantation

WANG Ling-Fei,YANG Rui-Bo,ZHAO Shao-Zhen
2013-01-01
Abstract:Objective To evaluate the visual quality after CACHET phakic intraocular lens implantation for the correction of high myopia.Methods A total of 22 cases(41 eyes) with high myopia treated with CACHET phakic intraocular lens implantation were collected in our hospital from April 2010 to October 2011 and followed up for one year.Uncorrected visual acuity(UCVA),best spectacle-corrected visual acuity(BSCVA),near visual acuity,refraction,wavefront aberrations,contrast sensitivity,visual symptoms and patient satisfaction were analyzed by statistical analysis before operation and 1 month,3 months,6 months,1 year after operation.Results At postoperative 1 year,41 eyes achieved a UCVA of 0.5 or better,36 eyes had a UCVA of 0.6 or better,34 eyes had a UCVA of 0.8 or better,and 24 eyes had a UCVA of 1.0 or better;BSCVA of 0.5 or better was achieved by 41 eyes,34 eyes achieved a BSCVA of 1.0 or better.There was no statistically significant difference before and after operation in near visual acuity,but the reading distance increased from 5-10(8.1±2.2)cm to 25-40(30.2±5.1)cm.The mean spherical equivalent refraction reduced significantly from preoperative(-12.12±2.79)D to postoperative 1 year(-0.45±0.36)D(P<0.01),which remained stable at subsequent follow-up(P>0.05).At postoperative 1 month,RMS of trefoil aberration increased significantly(t=2.153,P<0.05),while RMS of coma,trefoil and spherical aberration did not change significantly before operation and 3 months,6 months and 1 year after operation(both P>0.05).There was no significant difference in contrast sensitivity before operation and 1 month after operation(both P>0.05),but contrast sensitivity Log at 3.0 c·d-1 and 6.0 c·d-1 spatial frequencies under photopic condition both increased significantly 3 months after surgery(both P<0.05);Contrast sensitivity Log increased significantly at middle and central spatial frequencies from postoperative 6 months to 1 year(both P<0.05).At postoperative 1 month,17 patients(33 eyes) had no visual symptoms,while 2 patients(3 eyes) had glare and 3 patients(5 eyes) had halos;At postoperative 3 months,the percentage of glare and halos decreased to 0 and 7.3% respectively;At post-operative 6 months,all visual symptoms almost disappeared.Conclusion CACHET phakic angle-supported intraocular lens implantation can provide excellent corrective effect of refractive error,dose not cause changes of higher order aberrations and can increase the contrast sensitivity,and the postoperative visual symptoms are mild.
What problem does this paper attempt to address?