Establishment of Quick PCR Test for Detecting Actinobacillus Pleuropneumoniae

王贵平,何启盖,刘军发,蔡旭旺,陈焕春
DOI: https://doi.org/10.3969/j.issn.1005-4545.2004.02.009
2004-01-01
Abstract:A quick polymerase chain reaction test was established successfully.According to the apxⅣA gene sequence,a pair of specific primers which being able to amplificate a 422 bp fragment was designed to detect APP and its accuracy and sensitivity were confirmed.The 422 bp specific band could be amplified with 13 APP standard strains of serotype 1-13 by this PCR test,but could not be amplified with some bacterical strains as Hps,Bordetella bronchiseptica,Bordetella bronchiseptica E.coli,S.aureus,S.suis.68 CFU/mL was the lowest detecting limit for mixed bacterical solution of APP with the D_(600) of 0.003.APP could be detected more quickly and exactly by this PCR test from bacterical admixture having been cultivated for 8 hours.