Influence of Negative Voltage on Hydrogen Permeation Barriers on the Surface of Zirconium Hydride

ZHONG Xue-kui,CHEN Wei-dong,YAN Guo-qing
DOI: https://doi.org/10.3969/j.issn.2095-2295.2011.02.015
2011-01-01
Abstract:Micro-arc oxidation technology was used to fabricate hydrogen permeation barrier on surface of zirconium hydride.Phosphate electrolytic liquid department was used,and the solution was composed of Na5P3O1012 g/L,NaOH1.5 g/L and Na2EDTA2 g/L.The positive voltage is 350 V,and the frequency is 200 Hz in the experiment.The negative voltage was changed from 120 V to 160 V in the processing of hydrogen permeation barriers.The XRD,SEM and weighting analytical methods were adopted to analyze the thickness,composition,structure and morphology of the barriers.The results show that thickness of the oxide layer decrease with increasing the negative voltage,and the thickness varied between 72.5~62 μm..The hydrogen permeability reduces factor(PRF values) of the oxide layers decreases from 9.8 to 7.6.Negative voltage had no obvious effect on composition and structure of the oxide layers.
What problem does this paper attempt to address?