First pass perfusion and viability MR imaging in myocardial infarction model of pigs: experimental study

ZHANG Bing,ZHU Bin,SHI Guang-fei,YU Hai-ping,LI Chen,LI Li-ming
DOI: https://doi.org/10.3321/j.issn:1003-3289.2007.03.006
2007-01-01
Abstract:Objective To evaluate the role of myocardial perfusion, viability and cine-MR imaging on pig myocardial infarction models. Methods Fourteen pigs with myocardial infarction (3 days), 12 pigs with myocardial infarction (3 weeeks) underwent MR scanning. Cine-MR imaging acquaired by BFFE sequence were used to analyze the motion of heart. T1-TFE sequence was used to detect the first pass perfusion after injection of 0.1 mmol/kg Gd-DTPA. Inversion recovery viability sequence was used to recognize the high signal in the infarct myocardia. Results The diagnostic sensitivity of the first pass perfusion weighted images was 92%. The findings of enhancement region or attenuation in the infarct myocardia of 3-day pigs, 3-week pigs were detected in the delayed viability sequence images. The diagnostic sensitivity of that was 75%. The myocardial wall of hyper enhancement had a weaken motion in cine-MR images, and the diagnostic sensitivity was 92%. The symptom of attenuation and keeping lower signal of myocardial wall in viability images was detected in the obvious fibrosis myocardia or scar. Conclusion The combination of all imaging findings in the first pass perfusion, viability imaging and cine-MR imaging can view the true infarction and scar of heart.
What problem does this paper attempt to address?