Colorimetric and Fluorescent Dual-Mode Measurement of Blood Glucose by Organic Silicon Nanodots
Dan Li,Na Li,Lihe Zhao,Shaomei Xu,Ying Sun,Pinyi Ma,Daqian Song,Xinghua Wang
DOI: https://doi.org/10.1021/acsanm.0c02758
IF: 6.14
2020-11-03
ACS Applied Nano Materials
Abstract:Organic silicon nanodots (OSiNDs) with ∼100% photoluminescence quantum yield (QY) were facilely prepared by a one-pot hydrothermal strategy and were particularly explored as a fluorescence indicator for biosensing in this work. Under the catalysis of glucose oxidase (GOx), hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) was produced during the oxidation of glucose. The consecutive oxidation of <i>p</i>-phenylenediamine (PPD) by H<sub>2</sub>O<sub>2</sub> and horseradish peroxidase (HRP) led to the production of PPDox (2,5-diamino-<i>N</i>,<i>N</i>′-di-(4-aminophenyl)-2,5-cyclohexadiene-1,4-diimine). Based on the chromogenic nature of PPDox and the inner filter effect (IFE) of PPDox on the OSiNDs, a dual-mode colorimetric and fluorescent assay for ultrasensitive detection of glucose in serum was established. The limit of detection (LOD) of the present assay is 0.36 and 0.06 μM for the colorimetric mode and the fluorescent mode, respectively. Good consistency of testing results obtained from the present assay and a commercial glucometer demonstrated good reliability and application potential of the present assay for clinical diagnosis. By extending the applications of both fluorescent OSiNDs and the routine chromogenic reagent PPD, the ultrasensitive fluorescent approach of the present assay provided an effective tool for future screening of biological substances involved in H<sub>2</sub>O<sub>2</sub>-generation reactions.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsanm.0c02758?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsanm.0c02758</a>.The TEM image, size distribution, the FT-IR absorption spectrum, and the XPS spectra of OSiNDs (Figures S1 and S2); excitation wavelength-dependent fluorescence quenching behavior of the OSiNDs in the presence of PPDox (Figure S3); the optimization of reactive conditions for colorimetric and fluorometric sensing of H<sub>2</sub>O<sub>2</sub> and glucose (Figures S4 and S5); reversibility of this assay for detecting H<sub>2</sub>O<sub>2</sub> (Figure S6); detection results of glucose in serum and spiked samples by the present assay and a commercial glucometer (Table S1); and the analytical performance comparison of the present assay and recently reported methods for monitoring H<sub>2</sub>O<sub>2</sub> (Table S2) (<a class="ext-link" href="/doi/suppl/10.1021/acsanm.0c02758/suppl_file/an0c02758_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology