Possibilities and Limitations of Scanning Electrochemical Microscopy of Mg and Mg Alloys
S. Thomas,J. Izquierdo,N. Birbilis,R.M. Souto
DOI: https://doi.org/10.5006/1483
2015-02-01
CORROSION
Abstract:Mg and its alloys undergo corrosion at high rates in aqueous electrolytes, releasing copious amounts of hydrogen, making conventional SECM measurements upon Mg difficult. Issues associated with Mg SECM, and strategies to counter these, are discussed. SECM has been employed in Sample Generation-Tip Collection (SG-TC) mode to image cathodic sites upon Mg, wherein, the Pt tip oxidises hydrogen emanating from the specimen. This mode of SECM does not clearly reveal a correspondence between the microstructure and its associated reactivity; hydrogen currents measured by the Pt tip found to vary by an order of magnitude with time. Convective fluxes due to hydrogen bubbles, acidification from protons during hydrogen oxidation, and the NDE of Mg contribute to these high tip currents. SECM has also been performed on Mg using Mg2+ ion selective electrodes (ISEs), where an Mg2+ ionophore cocktail serves as a Mg2+ ion permeable membrane. The Mg2+ ions diffuse/migrate through the membrane which eventually settles at the equilibrium membrane (Donnan) potential. This potential varies with the logarithm of Mg2+ concentration, and can used to ascertain local Mg2+ concentrations (or anodic sites) on the surface. This technique needs to be complimented with other modes of SECM to obtain holistic electrochemical micrographs of Mg surfaces.
materials science, multidisciplinary,metallurgy & metallurgical engineering