A Multicentral Quality Assurance Study of Target Volume Delineation for A Prospective, Random, Multicenter Study: 3JECOG P-01

X. Chang,Z. Xiao,X. Wang,Y. Tian,W. Zhang,J. Q. Chen,K. X. Zhang,G. Li,X. Qiao,C. Han,Y. T. Wang,M. L. Liu,X. C. Sun,X. S. Gao,Y. Shi,F. Zhang,Z. L. Yu,J. Yang,Y. D. Zhao,H. Ge
DOI: https://doi.org/10.1016/j.ijrobp.2018.07.1331
2018-01-01
Abstract:3JECOG P-01 is a prospective, random, multicenter study of simultaneous integrated boost intensity modulated radiation therapy (SIB-IMRT) with S1 in elderly patients with esophageal cancer (EC). The purpose of our study is to discover the difference in target delineation among different hospitals, and explore a possible method to achieve higher quality assurance. Three representative EC patients,including upper, middle, and lower thoracic portions, were selected and sent to each hospital to be contoured based on their own contouring principles for the first time. Subsequently, a contouring protocol, revised at the second Multicenter Conference, was sent to each center for the second time of contouring.After completion, an experienced physicist was invited to accomplish all radiotherapy plans. The degree of target dispersion was quantified using standard deviation (St.D) for both target volumes and dosimetric parameters, as well as spatial conformability (SC) for the spatial overlap of multicenter target volumes. We defined the first contouring volumes as the routine group and the second as the protocol group. A total of 16 radiation oncologists were involved in this study, of which 9 provided both groups of target volumes. For distal case, degree of target dispersion in clinical target volume (CTV) and mean lung dose (MLD) was large between the two groups, with St.D of 80.54, and 114.07 in the routine group , comparing individually with 65.84 and 65.39 in the protocol group. Besides, SC in PTV and gross tumor volumes(GTV)showed an significant enhancement, from 0.42 and 0.40 to 0.56 (P=0.009) and 0.74 (P=0.005).Similar results were observed in upper and middle cases, in that SC in GTV enhanced significantly, and St.d in dosimtric parameters was reduced to a certain extent. This is in contrast to SC in CTV, which did not achieve significant increase. Significant intercentral variation was observed in SIB-IMRT fields for elder EC patients, especially for those cases with distant lymph node metastasis. A clear contouring protocol, evidently necessary for mandatory quality assurance, can ensure that the degree of dispersion in target volumes, as well as its relative dosimetric parameters, are controlled. Ultimately this will ensure a solid foundation for the reliability of the research results.
What problem does this paper attempt to address?