Effect of Liquid Withdraw Technique on the Incidence of Pneumothorax and Tumor Tissue Amount of CT-guided Cutting Needle Lung Biopsy: an Expanded Retrospective Study.

Rutian Li
DOI: https://doi.org/10.1200/jco.2017.35.15_suppl.e20535
IF: 45.3
2017-01-01
Journal of Clinical Oncology
Abstract:e20535 Background: CT-guided cutting needle lung biopsy is important for the diagnosis of lung cancer especially in the area of precision medicine. In ASCO 2015, we reported that “Liquid withdraw” technique (to inject small amount of liquid while withdraw of the needle) can prominently reduce incidence of pneumothorax when combined with co-axial technique in 38 cases. In this reported, we retrospectively studied 90 patients undergoing CT-guided cutting needle lung biopsy to investigate the role of this technique in reducing complications and promoting biopsy effectiveness. Methods: From Jan 1st, 2014 to Nov 30th, 2016, we retrospectively studied 92 CT-guided percutaneous lung biopsies using co-axial and liquid withdraw techniques in 90 patients. The pathologies and complications secondary to biopsy procedure were noted. Pneumothorax and bleeding was graded as mild (mild and very mild), moderate, and severe. Results: 88 cases were diagnosed out of 92 biopsies (95.7%), of which 60 cases were adenocarcinoma. Liquid withdraw technique assured adequate tissue for diagnosis and treatment planning of lung cancer. Among 71cases diagnosed as NSCLC, only 5 (7.0%) were diagnosed as NOS. Among 52 cases of adenocarcinoma who consented EGFR mutation test, only 1 case (1.9%) failed due to insufficient tissue. Among all the biopsies, when acquiring specimens 4-6 times per procedure, the incidence of pneumothorax was in 18 cases (19.6%), among which 13 cases (14.1%) were very mild pneumothorax (lung surface retraction of≤1 cm), mild and moderate pneumothorax accounted for just 4.3%. No severe pneumothorax occurred. 19 cases (20.7%) happened bleeding (18 cases were mild bleeding). No infection, tumor implantation or aeroembolism happened. Conclusions: Compared to lung biopsy without liquid withdraw, the incidence of pneumothorax was reduced from approximately 35% to 19.6%. The liquid withdraw technique also resulted in low rate of other complications and adequate tissue for diagnosis. Next, we are planning to conduct a prospective study to further evaluate the role of this technique in the precision diagnosis and treatment of lung cancer.
What problem does this paper attempt to address?