Interactive Display Methods Of Vessel Of Interest Within Voxelized Three - Dimensional Cardiac Model

Ren Guo-Yin,Lv Xiao-Qi,Yang Nang,Yu Da-Hua
DOI: https://doi.org/10.3788/YJYXS20183305.0433
2018-01-01
Chinese Journal of Liquid Crystals and Displays
Abstract:In the paper, the linear octree was used to separate the 3D model of the heart into voxels and to achieve the purpose of rapid display of any interested vessels. After the 3D model is separated into voxels, the polygon area is used to select inside voxels of VOL Based on the topological relation of 26-adjacent voxels and the similarity of voxel mutual information, the final optimal depth and best mutual information threshold are confirmed as respectively 14 and -1.375, thus discovering the voxel set of the same tissue in the volume of interest. The technology ultimately achieves the precise display of any VOI from a medical image. This technique can be viewed as a process of extracting any local three-dimensional model with an extraction tool and performing a four-dimensional dynamic display. Experimental results show that compared with C-V 3D segmentation algorithm accuracy of 90.1% the average accuracy of this segmentation algorithm has reached 96.02%; running time is shortened from 13.8 s to 10.7 s; 4D playback framer has reached its maximum 40 FPS, which basically meets the clinical needs of vascular 3D segmentation. It is not only a good way to quickly analyze the physiological and pathological characteristic for the local lesion, but it is more intuitionistic and convenient for doctors to observe the actual condition of any local blood vessel of the patient's heart, which contributes to clinical decision-making.
What problem does this paper attempt to address?