Dynamic Characteristics and Modeling of Air Conditioner Loads
LI Yuyan,CHEN Qian,HUANG Wenying,FANG Zhaoxiong,CHEN Feng,ZHAO Hongga,HAN Jingdong,JU Ping
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.01.014
2007-01-01
Abstract:Based on the characteristic analysis and modeling of a single air conditioner, the dynamic characteristics and modeling of air conditioner flock are analyzed by using PSASP and expanding a distribution network. Two conditions are included: full air conditioner load and composite load of air conditioners, motors and resistances. When the voltage is above critical value, the Karlsson-Hill model is suitable. To consider the starting characteristic, several assumptions are made, including that all air conditioners start simultaneously, uniformly and randomly. For the simultaneous start, the air conditioner flock can continue to use the starting model of single air conditioner, while for the uniform start and the random start, the power can be fitted by sectional functions. The influence of air conditioner flock on power network is analyzed, in which its restarting effect following voltage recovery is emphasized. Simulation results show that, the impact on 10 kV bus is greater than that on 0.4 kV bus; impact of full air conditioner load is greater than that of composite load; the impact of simultaneous start is greater than that of normal start, and the impact of uniform start is the smallest.