Microfluidic Mixing Through Oscillatory Transverse Perturbations

J. W. Wu,H. M. Xia,Y. Y. Zhang,P. Zhu
DOI: https://doi.org/10.1142/s0217984918400304
2018-01-01
Modern Physics Letters B
Abstract:Fluid mixing in miniaturized fluidic devices is a challenging task. In this work, the mixing enhancement through oscillatory transverse perturbations coupling with divergent circular chambers is studied. To simplify the design, an autonomous microfluidic oscillator is used to produce the oscillatory flow. It is then applied to four side-channels that intersect with a central channel of constant flow. The mixing performance is tested at high fluid viscosities of up to 16 cP. Results show that the oscillatory flow can cause strong transverse perturbations which effectively enhance the mixing. The influence of a fluidic capacitor in the central channel is also examined, which at low viscosities can intensify the perturbations and further improve the mixing.
What problem does this paper attempt to address?