Calculation of Ground View Factor As an Index for Urban Thermal Environment Optimization

Zaoshi Jiang,Wei You,Wowo Ding
DOI: https://doi.org/10.1016/j.egypro.2017.12.375
2017-01-01
Energy Procedia
Abstract:Urban form is a key factor affecting the urban heat island (UHI) which leads to increased temperatures, air pollution, and energy consumption. One commonly utilized parameter to understand the urban form is the sky view factor (SVF), which represents the proportion of the sky visible from a given location. SVF is widely used to study the thermal environment near ground. However, SVF cannot fully describe the building arrangement. Also, a lot of aerial field measurements are needed to investigate the thermal environment in air. With the development of unmanned aerial vehicle (UAV) technologies, temperature and humidity information at different heights of typical samples can be collected, while aerial photos can be shot for further analysis such as calculation of ground view factor (GVF) which represents the proportion of the ground visible from a given location and may describe more site information. This paper presents a comparison between two methods for calculations of GVF, whose values are calculated with a photographic method and a vector-based method on rhino-grasshopper platform. Meanwhile, a case study of GVF and SVF distributions in continuous 3D space are shown for later research of exploring the relationship with temperature field.
What problem does this paper attempt to address?