Effect of Ribbed and Smooth Coolant Cross-Flow Channel on Film Cooling

Wei Peng,Xiaokai Sun,Peixue Jiang,Jie Wang
DOI: https://doi.org/10.1016/j.nucengdes.2017.03.015
IF: 1.7
2017-01-01
Nuclear Engineering and Design
Abstract:The influence of ribbed and unribbed coolant cross-flow channel on film cooling was investigated with the coolant supply being either a plenum-coolant feed or a coolant cross-flow feed. Validation experiments were conducted with comparison to numerical results using different RANS turbulence models showed that the RNG k-epsilon turbulence model and the RSM model gave closer predictions to the experimental data than the other RANS models. The results indicate that at a low blowing ratio of M = 0.5, the coolant supply channel structure has little effect on the film cooling. However, at a high blowing ratio of M = 1.0, the adiabatic wall film cooling effectiveness is significantly lower with the plenum feed than with the cross-flow feed, especially for the cases with ribs. The film cooling with the plenum model is better at M = 0.5 than at M = 1.0. The film cooling with the cross-flow model is better at a blowing ratio of M = 0.5 in the near hole region, while further downstream, it is better at M = 1.0. The results also show that the coolant cross-flow channel with V-shaped ribs has the best adiabatic film cooling effectiveness. (C) 2017 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?