Abstract:Objective To investigate the effects of different cyclic tensile strain on the proliferation of human anulus fibrosus cells from degenerated discs.Methods Anulus fibrosus(AF) cells were isolated from a degenerated human IVD,expanded in monolayer,and cyclically strained for 3 hours,applying 0,5%,10%,15% and 20% strains at a frequency of 0.25 Hz with the use of the DioDynamic test instrument.The flow cytometry method was used to examine the Af cells proliferation at 24 hours following application of the cyclic tensile strains.Results The proliferative index (PI) increased with the magnitude value of cyclic tensile strain except 20% group.The most significant increase of proliferation index were found in 15% group.Conclusion There might be some corelationships between magnitude of cyclic tensile strain and the proliferation of the degenerative AF cells.