Maximum Torque Output for Volts/hz Controlled Induction Machines in Flux-Weakening Region

Kai Wang,Kevin Lee,Wenxi Yao,Fayi Chen
DOI: https://doi.org/10.1109/ecce.2016.7855236
2016-01-01
Abstract:For maximum torque control of induction machines (IM) in flux-weakening region, the following problems exist: 1. In Volts/Hz scalar control mode, a slow frequency ramp time cannot provide sufficient electromagnetic torque, whereas the excessive acceleration leads to overcurrent shutdown and system collapse; 2. In vector control mode, the under-estimated leakage inductance in field-weakening region can lead to system instability. To solve these problems, this paper presents a method based on both stability criteria and maximum torque capability for determining a proper frequency ramp-up profile. It retains the maximum torque output capacity on the basis of guaranteeing system stability in flux-weakening region. A proportional and integral (PI) controller is employed to adjust the frequency ramp time, which will be halted if the magnetizing current exceeds a predefined limit. Moreover, the proposed scheme has a larger tolerance of underestimated leakage inductance as compared with the vector controlled IM drives in flux-weakening region. Simulation studies on a 3hp (2.2kW) and a 20hp (15kW) have been conducted in both Volts/Hz and vector control modes. Experimental validation is presented on a 3hp (2.2kW) platform in Volts/Hz control mode. Both simulation and experimental results validate the analysis and show effectiveness of the proposed method in the defined scenarios.