Agreement Assessment in Size Measurement of Hepatic Metastases

Yangchen Zheng,Ibrahim Karademir,Leon Wise,Aytekin Oto,Yahui Peng
DOI: https://doi.org/10.1117/12.2265986
2017-01-01
Abstract:The purpose of the study was to investigate patient-wise agreement among multiparametric magnetic resonance (MR) imaging sequences and radiologists, respectively, in the size assessment of hepatic metastases. A total of 30 liver metastases were identified from 20 patients and three radiologists independently measured the long and short axes for all metastases in T1-weighted, T2-weighted, diffusion-weighted imaging (DWI) with b of 0 and 800 s/mm(2), and the apparent diffusion coefficient (ADC) map. We calculated the patient-wise intraclass correlation coefficient (ICCs) to estimate the interobserver and intersequence agreement in measured lesion size. Interobserver ICCs were 0.92-0.98 for different MR sequences and intersequence ICCs were 0.93-0.98. In conclusion, multiparametric MR imaging is a reliable tool for hepatic metastatic lesion measurement.