P3.02b-100 Comparison of Three T790M Testing Methods for the Detection of Non-Small Cell Lung Cancer after Tyrosine Kinase Inhibitor Failure

Lucheng Zhu,Shirong Zhang,Bing Xia,Xueqin Chen,Limin Wang,Hong Jiang,Xufeng Chen,Shenglin Ma
DOI: https://doi.org/10.1016/j.jtho.2016.11.1767
IF: 20.121
2017-01-01
Journal of Thoracic Oncology
Abstract:The third generation of TKI showed promising activities in patients with acquired T790M mutation. However, many patients in this setting are unable to undergo rebiopsy due to limited tissue availability and procedural feasibility. Mutation detection in plasma has shown promises to conquer the clinical challenging of re-biopsy, with advantage of non-invasiveness and accessibility. Here, we chose and evaluated the performance of three methods, amplification refractory mutation system (ARMS), modified amplification refractory mutation system (SuperARMS), and droplet digital PCR (ddPCR), to assess their concordance and feasibility for the detection of mutations in plasma samples. This study was performed between March 2015 and March 2016. Patients were considered eligible and were enrolled in this study if they met the following criteria: 1) histologically confirmed stage IIIB/IV NSCLC; 2) clinically resistant to first-generation EGFR-TKIs according to Jackman’s criteria. Blood samples were collected within 14 days after TKI resistance. Each sample was simultaneously detected by three methods. In total, 169 patients were enrolled. 54.4% were female and 72.2% were diagnosed as stage IV; 97.6% were adenocarcinoma. The rates of patients in response to EGFR-TKI treatment were 35.5% for stable disease, 52.1% for partial response and 12.4% for complete response, respectively. T790M mutations were detected in 54 of 169 (32.0%) samples by ARMS, 33 of which simultaneously carried exon19 deletions and 21 of which carried L858R. For SuperARMS assay, 59 (34.9%) samples were detected T790M mutation and 110 (65.1%) were not detected. ddPCR results showed that 61 (36.1%) samples were with detectable T790M mutation and 108 (63.9%) samples were detected with wildtype T790M. T790M abundance ranged from 0.04% to 38.2%. The median T790M abundance was 0.15% for total samples and 2.98% for T790M mutation samples. The overall concordance was 81.1% (137/169) among ARMS, SuperARMS, and ddPCR. The crude and adjust agreement between ARMS and SuperARMS was 87.6% and 86.1%, 88.8% and 87.7% between ARMS and ddPCR, 85.8% and 84.5% between SuperARMS and ddPCR, respectively. We also found that detection of T790M with ddPCR showed a sensitivity of 94.6% (95%CI: 90%-97.5%) and a specificity of 59.9% (95% CI: 51.2%-67.9%) when took ARMS as reference. Liquid biopsy showed promises with advantage of non-invasiveness and accessibility. T790M detection based on plasma circulation tumor DNA showed high concordance. Compared with non-digital platforms, ddPCR showed higher sensitivity and provided both frequency and abundance information, which might be important for treatment decision-making.
What problem does this paper attempt to address?