Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

Cheng Li,Le Li,Junming Li,Yajun Zhang,Zhihui Li
DOI: https://doi.org/10.1016/j.nucengdes.2016.12.022
IF: 1.7
2017-01-01
Nuclear Engineering and Design
Abstract:•Heat removal by steam condensation, thermal conduction and evaporation is the most important scheme for AP1000 PCCS. Traditionally, studies on containment wall condensation and evaporation have been widely made, while it lacks studies on the shell two-dimension (2-D) thermal conduction. Currently, based on the known heat and mass transfer correlations and the phenomenon from water wetted coverage test, the physical model for 2-D thermal conduction is given and numerical simulation is then made. By discussions, it forms the following highlights.•The partially wetted surface can enhance the whole heat transfer process (including inner condensation, wall thermal conduction and outside cooling) and the maximum enhancement factor can be as large as 63%. There is an enhancement peak at around dry strip fraction a=90%. When L is less than 0.03m, its influence on heat transfer is small and the enhancement is mainly affected by dry coverage. However, for larger L, both α and L contribute much to larger enhancement.•Location at the spring line is often used for safety analysis and the dry strip fraction there for AP1000 is mainly at 10%–80%. Accordingly, further analysis is made on L (0.03<L<0.3) and a fitting expression is given for α=10%–80%. It could be used to improve the corresponding software and it could also be used for containment scaling-down criteria analysis.
What problem does this paper attempt to address?