Research on the Fault Diagnosis Method for Slip Ring Device in Doubly-Fed Induction Generators Based on Vibration

Hongzhong Ma,Taotao Chen,Yan Zhang,Ping Ju,Zhenfei Chen
DOI: https://doi.org/10.1049/iet-rpg.2016.0288
IF: 3.034
2017-01-01
IET Renewable Power Generation
Abstract:The brush and slip ring system is an important part of excitation system in doubly-fed induction generators, but the excitation instability caused by the surface damage of slip ring often occurs, which brings a great security trouble to the stable operation in the generator. To solve this problem, the method that the vibration signal is used to carry out diagnosis of slip ring surface in different fault states was proposed. First, the principle based on vibration, the transmission route and failure mechanism of the slip ring were analysed. Then, the experiment platform of the brush and slip ring was set up; the real-time vibration signal was collected before and after fault; the wavelet energy spectrum was applied to the vibration signal processing. The abnormal vibration band was found by the contrast and proportion analysis of the wavelet energy spectrum distribution of vibration signals before and after fault, which can be the basis for fault diagnosis of the slip ring device.
What problem does this paper attempt to address?